  • Michigan plumbing code book: which edition to buy and where to read it

    Which Michigan plumbing code book should you have on the truck? As of Nov 19, 2026, it’s the 2021 Michigan Plumbing Code for commercial and multifamily work, and the 2015 Michigan Residential Code for one- and two-family homes. The 2024 plumbing code isn’t in effect yet. Here’s which book to buy, where to get it, and where to read it free.

    The current Michigan plumbing code book

    • LARA lists the 2021 Michigan Plumbing Code as the current code, effective March 12, 2024, and notes that “Residential requirements are contained in the Michigan Residential Code” (LARA code books).
    • The rule in force adopts the International Plumbing Code (IPC), “2021 second printing edition, including appendices B, C, D, and E,” minus a list of excluded sections (R 408.30701). Michigan then amends many IPC sections in R 408.30711–30796. A plain 2021 IPC book doesn’t have those Michigan amendments, so use the Michigan edition or keep the Part 7 rules with your IPC.
    • When the rules were adopted, the book could be bought from the International Code Council (ICC) through the bureau’s website for $87.50, and it can be inspected at the Bureau of Construction Codes office, 611 West Ottawa Street, Lansing (R 408.30701). The ICC sets the current price.

    Houses use a different book

    The Michigan Plumbing Code’s scope sends detached one- and two-family homes, and townhouses no more than 3 stories high with separate means of egress, to the Michigan Residential Code (R 408.30711, section 101.2 exception). For that work you need the 2015 Michigan Residential Code. LARA lists it as current, effective February 8, 2016 (LARA code books), and it stays in effect while a court order blocks the 2021 update (LARA Currently Open Rules). LARA also posts a free 2015 Michigan Residential Code Errors and Conflicts document. Keep it with that book.

    Where to buy, and where to read free

    The 2024 Michigan Plumbing Code: not yet

    The 2024 IPC rule set has final rules posted, but the 2025-8 LR tracker still shows Filing date: Pending and Effective date: Pending as of Nov 19, 2026. The final rule language says the rules take effect 120 days after filing. It would adopt the IPC “2024 first printing: June 2023 edition,” exclude appendices A and F, and make appendix E mandatory. A 2024 IPC book isn’t the Michigan code until that happens.

    A new book also means a course

    When the state construction code changes, master and journey plumbers must complete a board-approved course on the update within 12 months of the change to renew (MCL 339.6113(2); MCL 339.6115(3)). Plan that once the 2024 rules have an effective date.

    What to do

    • Commercial or multifamily: get the 2021 Michigan Plumbing Code, or a 2021 IPC plus the Part 7 Michigan amendments.
    • Houses: get the 2015 Michigan Residential Code and LARA’s errors and conflicts sheet.
    • Hold off on treating a 2024 book as the Michigan code until the 2025-8 LR tracker shows a filing date.

    Sources: LARA code books · R 408.30701–30796 · R 408.30500–30547g · LARA Currently Open Rules · 2025-8 LR tracker · MCL 339.6113

    More for Plumbing contractors: Michigan Plumbing updates.

    Want a free sample issue? Sign up for the free sample. Pick your trades and we’ll email you the sample PDF.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Nov 19, 2026. Confirm with LARA or your local building department before you act.

  • Michigan plumbing code venting under the 2021 IPC

    Michigan’s plumbing venting rules come from the 2021 International Plumbing Code as amended in Part 7 of the Construction Code. Houses follow the residential code instead. The 2024 IPC adoption is still waiting to be filed — it is not the code in force today.

    Why it matters

    • Current rules adopt the international plumbing code, 2021 second printing (with listed Michigan exceptions) as the Michigan Plumbing Code (R 408.30701).
    • Amended section 101.2 sends detached 1- and 2-family dwellings and townhouses not more than three stories with separate means of egress, and their accessory structures, to the Michigan Residential Code for plumbing (R 408.30711, section 101.2). Use that residential text for house jobs.
    • Rule set 2025-8 LR would move Michigan to the 2024 IPC. As of Nov 5, 2026, its Filing date and Effective date are both Pending (final rules and JCAR package are posted). It takes effect 120 days after filing once filed. Until then, design and inspect to the 2021 IPC as amended.

    Where to read the adopted IPC text

    Michigan’s Admin Code states the amendments and which model-code sections are adopted or excepted. For the model IPC wording Michigan did not rewrite — including Chapter 3 pipe support / hanger provisions — use the free ICC Digital Codes Michigan viewer named on MCB’s resources list (codes.iccsafe.org/codes/united-states/michigan) or buy the book through LARA’s code-books channel referenced in R 408.30701. The Michigan amendments below are quoted from the Admin Code PDF.

    Trap-to-vent distance and fixture-drain vents

    Michigan amends IPC section 909.1:

    • 909.1 Distance of trap from vent. Each fixture trap shall have a protecting vent located so that the slope and the developed length in the fixture drain from the trap weir to the vent fitting are within the requirements in table 909.1 (R 408.30723).

    Michigan amends section 909.2:

    • 909.2 Venting of fixture drains. The vent for a fixture drain, except where serving a fixture with integral traps such as water closets, shall connect above the weir of the fixture trap being vented. The total slope shall not exceed the diameter of the fixture drain (R 408.30725c).

    Use table 909.1 from the adopted 2021 IPC for the developed-length numbers; Michigan points to that table rather than reprinting it in the Admin Code.

    Combination waste and vent

    Michigan adds section 915.1:

    • A combination waste and vent system shall not serve fixtures other than floor drains, sinks, lavatories and drinking fountains. Combination waste and vent systems shall not receive the discharge from a food waste disposer or clinical sink (R 408.30725d).

    Roof terminations and frost closure

    Michigan’s roof and exterior vent amendments:

    • 903.1 Roof extension. Open vent pipes through a roof terminate at least 1 foot (305 mm) above the roof, except that if the roof is used for any purpose other than weather protection, vent extensions run not less than 7 feet (2134 mm) above the roof (R 408.30753a).
    • 903.1.1 Roof extension unprotected. Open vent pipes through a roof terminate not less than 12 inches (304.8 mm) above the roof (R 408.30753b).
    • 903.2 Frost closure. To prevent frost closure, every vent extension through a roof shall be a minimum of 3 inches (76 mm) in diameter. Any increase in vent size shall be made inside the building a minimum of 1 foot (305 mm) below the roof or inside the wall (R 408.30754a).
    • 903.7 Extensions outside a structure. Vent pipes installed on the exterior of the structure shall be protected against freezing by insulation or heat, or both (R 408.30754b).

    Hanger and pipe-support spacing

    Part 7’s Michigan amendments reviewed Nov 5, 2026 do not rewrite the IPC pipe-hanger or support spacing tables. Those spacing rules remain the adopted 2021 IPC text (commonly Chapter 3 general regulations / pipe support). Do not treat trade-press summaries as the Michigan rule. Open the adopted IPC in the ICC Michigan free viewer or the purchased Michigan Plumbing Code book, and follow any jobsite instructions from the enforcing agency.

    What to do

    • On commercial and multifamily work under the Michigan Plumbing Code, apply the Michigan amendments above first, then the rest of the 2021 IPC as adopted.
    • On 1- and 2-family houses, switch to the Michigan Residential Code plumbing chapters (101.2).
    • Watch the 2025-8 LR tracker for a filing date before you train crews on 2024 IPC venting changes.

    Sources: R 408.30701–30796 · 2025-8 LR tracker · ICC Digital Codes: Michigan

    Want a free sample issue? Sign up for the free sample. Pick your trades and we’ll email you the sample PDF.

    More for Plumbing contractors: Michigan Plumbing updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Nov 5, 2026. Confirm with LARA or your local building department before you act.

  • How to look up a Michigan plumbing license

    Need to check a plumber’s license in Michigan? LARA’s Bureau of Construction Codes has a free public lookup. Use it before you hire a sub, take on a journey plumber, or let someone pull a permit on your job.

    Why it matters

    • Only a licensed master or journey plumber may perform plumbing, apart from the exceptions in the law. A licensed master plumber must be in charge, and the responsible plumbing contractor must get the permit (MCL 339.6107(1)).
    • A license or registration lapses the day after its expiration date. After that, the person can’t practice or use the title until it’s renewed (MCL 339.411(1)). Late renewal is allowed within 60 days with a late fee (MCL 339.411(2)).

    How to look up a plumbing license

    1. Open LARA’s Find / Verify a BCC Licensed Professional or Business search (Accela). It’s free and needs no login.
    2. Pick the License Type. The plumbing choices are Plumbing Apprentice, Plumbing Journey, Plumbing Master and Plumbing Contractor (there’s also a Plumbing Affidavit type).
    3. Search by License Number if you have it. Otherwise use Last Name and First Name, or Business Name for a company. City and Zip help narrow a common name.
    4. Read the results table: License Number, License Type, Business Name, name, License Expiration Date, City, State and Zip. Click a result for more details. You can also download the results.

    Watch out: the search returns expired licenses too. In a test search on Oct 19, 2026, results included plumbing contractor licenses with expiration dates years in the past. A listing alone doesn’t mean the license is active. Check the date.

    Reading the expiration date

    From LARA’s license renewals page:

    • Master plumber and plumbing contractor: renew every three years by April 30. Not everyone renews in the same year.
    • Journey plumber and apprentice plumber: renew every year by April 30.
    • Plumbing contractor license numbers start with 80. If someone holds both the contractor and the qualifying master license, renewing the contractor number renews both.

    So a journey plumber whose record shows an expiration date of April 30, 2026 or earlier, and no newer date, has a lapsed license under MCL 339.411 unless LARA’s record shows a renewal.

    Coming up: “on hold” contractor records

    Today, if a master plumber stops representing a plumbing contractor, the contractor license may be summarily suspended until a new master is designated (current R 339.5411(2)).

    The pending Skilled Trades rules rewrite would change that wording. The final rule language says the contractor license “is placed in abeyance and displays as on hold in the department’s public record,” and no further permits issue while it’s on hold (final R 339.5411(2), state rule tracker, 2025-58 LR). As of Oct 19, 2026, the rule set’s Filing date and Effective date are Pending; it takes effect 90 days after filing. Once it’s in effect, an “on hold” status in the lookup is something to ask about before that contractor pulls your permit.

    What to do

    • Look up every plumbing sub before they start. Match the business name and the Plumbing Contractor number (80…) to the permit.
    • Save a screenshot or the downloaded result in the job file.
    • Check your own crew’s journey and apprentice dates before April 30.

    Sources: LARA BCC license lookup · LARA renewals · MCL 339.6107 · MCL 339.411 · 2025-58 LR tracker

    Want a free sample issue? Sign up for the free sample. Pick your trades and we’ll email you the sample PDF.

    More for Plumbing contractors: Michigan Plumbing updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 19, 2026. Confirm with LARA or your local building department before you act.

  • Residential code on hold: what it means for plumbing on houses

    Michigan tried to update its residential code to parts of the 2021 IRC and the residential energy code to the 2021 IECC. A court put that on hold.

    The facts

    • The two rule sets were set to take effect Aug 29, 2025.
    • On July 7, 2025, the Michigan Court of Claims issued a stipulated order in Home Builders Assoc. et al. v. LARA et al. It stops LARA from “taking additional steps necessary to apply or implement” them while the case is pending.
    • Until it’s resolved, the 2015 IRC and IECC residential provisions Michigan adopted remain in effect.
    • As of Oct 15, 2026, LARA’s open rules page still says the 2015 versions “will remain valid and in effect” while the order stands.

    Why a plumber cares

    The IRC has its own plumbing chapters for one- and two-family homes. Michigan’s plumbing code says detached one- and two-family homes, and townhouses up to 3 stories with separate exits, “shall comply with the Michigan residential code” (Mich. Admin. Code R 408.30701, section 101.2 exception). Right now that’s the 2015-based residential code. Don’t assume the 2024 IPC update automatically covers single-family work.

    What to do

    • Keep doing houses to current Michigan rules, not “the new 2021 code” a builder read about.
    • Watch for the court outcome.

    Source: LARA BCC currently open rules

    More for Plumbing contractors: Michigan Plumbing updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.

  • Skilled Trades rules rewrite: what plumbers should know

    Michigan’s licensing rules for the trades come from the Skilled Trades Regulation Act. LARA is rewriting the rule set behind it.

    What LARA says it does

    • Sets “clear and consistent fees and experience requirements” for registrations, licenses and exam applications.
    • Addresses continuing education requirements.
    • Clarifies complaint procedures.
    • Moves the boiler rules out into a separate Boiler Code rule set.
    • Makes editorial and readability fixes.

    Timeline

    • Published in the Sept 1, 2026 Michigan Register.
    • Public hearing Sept 10, 2026. Comments closed Sept 11.
    • Takes effect 90 days after filing. As of Oct 15, 2026, the state has not filed it or published an effective date. Final rule text went to the Legislature’s rules committee Sept 29, 2026 (state rule tracker, 2025-58 LR).

    Why plumbers care

    If you’re sponsoring an apprentice toward journey, or a journey toward master, the experience paperwork or exam application fees could change. The final text is on the state rule tracker. It isn’t in effect yet, so today’s fees and rules still apply. Once it’s filed we’ll publish what actually changed.

    What to do

    • Before you submit any exam application in 2027, re-check LARA’s current requirements.
    • Subscribe: email LARA-BCC-Rules@michigan.gov with the rule set name in the subject.

    Source: LARA BCC currently open rules

    More for Plumbing contractors: Michigan Plumbing updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.

  • Plumbing license renewals and code-update courses in Michigan

    Two things trip people up: when you renew and whether you need a code-update course. Here’s the short version, straight from LARA.

    Renewal dates and fees

    License Renews Fee Late fee
    Apprentice plumber Every year by April 30 $15 $20
    Journey plumber Every year by April 30 $40 $100
    Master plumber Every 3 years by April 30 $300 $100
    Plumbing contractor Every 3 years by April 30 $300 $100

    Renewal opens 90 days early. Use Express Pay or your Accela account. If you hold both a contractor and a qualifying master license, entering the contractor number (starts with 80) renews both.

    The lapse traps

    • Apprentices: time without an active registration doesn’t count toward journey hours.
    • Journey plumbers: the master application needs two years immediately before applying. A lapse over 60 days restarts that clock.
    • Nobody is allowed on the job site without an active license.

    Code-update courses

    • Journey and master plumbers only take a code-update course within one year of a new code being adopted. It doesn’t happen every year.
    • Apprentices and the plumbing contractor license itself don’t need one.
    • You don’t send proof unless you’re audited. Keep your certificate.
    • LARA uses CE Broker to approve course providers and list courses: cebroker.com, or 877-434-6323.

    The law says the course is due “within 12 months after the update or change” in the state code (MCL 339.6113(2)). With the 2024 IPC on the way, that clock will apply once the new code takes hold. Neither the law nor LARA’s renewal page says whether it runs from the filing date or the effective date. Ask LARA in writing.

    Example

    Your journeyman’s license expires April 30. If he renews May 15, he pays $40 plus the late fee. If he lets it go to July, his master-eligibility clock resets. That’s a cheap mistake that costs a year.

    Sources: LARA renewals · LARA plumbing code update information

    More for Plumbing contractors: Michigan Plumbing updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.

  • What’s new in the 2024 IPC (and what Michigan might keep)

    Michigan’s proposed plumbing rules adopt the 2024 IPC with Michigan amendments. Here are the model-code changes ICC itself highlights. Big caveat: Michigan can amend or delete any of them. As of Oct 22, 2026, Michigan’s final rule text is posted but not yet filed or in effect (state rule tracker). One flag from the final rule text: Michigan’s section 312.1 says piping is tested with water, or with air for non-plastic piping. It does allow a low-pressure air test for plastic drain and vent piping under section 312.3. Check that before you count on the vacuum-test option. Treat this list as a heads-up, not a rulebook.

    ICC’s list of important changes

    From ICC’s own 2024 IPC description:
    – Tracer wire for buried plastic sewer piping. It’s a new requirement. A city summary of the changes describes it as minimum 14 AWG run along the full length.
    – Vacuum testing option for DWV piping. A new way to test drain-waste-vent systems. That could be handy in a Michigan winter, when water tests are a pain. Check the test method in the code.
    – Showerhead flow limited to 2.0 gpm, down from 2.5, with high-efficiency performance requirements.
    – Plastic pans under gas-fired water heaters must be tested to ASTM E84 or UL 723.
    – Buried piping support where there’s expansive soil under the building.
    – Group I occupancy fixture requirements significantly updated. These are healthcare and assisted-living type buildings.
    – Locking exception for multiple-user toilet room doors. Lets authorized personnel use special locks.
    – Installation standards for solvent-cemented plastic joints.
    – Standards for chemical waste piping materials.

    ICC also reformatted the 2024 books: single-column text, QR codes marking changes, and tables placed right after their sections. Your old page-flipping habits won’t match.

    What a small Michigan shop should watch

    • Sewer jobs: If the tracer wire rule survives, it’s material and labor on every plastic sewer run. Price it into bids once the rule is final.
    • Water heater swaps: Check that your pans meet the E84/UL 723 requirement.
    • Fixture spec: 2.0 gpm showerheads. Most current WaterSense heads already comply, but check your stock.

    Still open

    Sources: ICC 2024 IPC product page · ICC announcement · LARA open rules

    More for Plumbing contractors: Michigan Plumbing updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.

  • Michigan Plumbing Code is moving to the 2024 IPC: where it stands

    Michigan’s plumbing code is based on the International Plumbing Code (IPC). Right now it’s the 2021 IPC. LARA has proposed moving to the 2024 IPC.

    Where it stands

    • Rule set: Construction Codes, Part 7. Plumbing Code, LARA number 2025-8 LR.
    • The proposed rules were published in the July 15, 2026 Michigan Register.
    • The public hearing was Aug 5, 2026 in Lansing. Comments closed Aug 7, 2026.
    • It takes effect 120 days after LARA files it with the Secretary of State.

    Status: As of Oct 22, 2026, the state has not filed these rules or published an effective date. LARA posted the final rule text and sent it to the Legislature’s Joint Committee on Administrative Rules on Oct 19, 2026 (state rule tracker, 2025-8 LR). LARA’s report to the committee says it made no changes to the proposed rules based on public comments. Until it’s filed, and for 120 days after, the 2021 IPC governs.

    What LARA says it does

    It adopts the 2024 IPC “with amendments, deletions, and additions deemed necessary for use in Michigan.” It keeps Michigan-specific rules and drops IPC sections that don’t fit Michigan’s “geographic and environmental features.” LARA also says the update could save homeowners and contractors money by allowing newer materials and technology.

    What it means for you

    1. A code-update course clock starts. Journey and master plumbers have to take a code-update course within one year of a new code being adopted. See our CE explainer.
    2. Permits around the switchover. Which edition applies to a given job usually depends on when the permit is applied for. Ask your inspector which edition they’ll apply.
    3. Know the model-code changes. See what’s new in the 2024 IPC. Michigan can amend any of them. Its draft rule text is posted, but the final version isn’t out yet.

    Example

    You’re bidding a small commercial build-out in January for a spring rough-in. If the 2024 IPC takes effect in between, ask the inspector which edition they’ll hold you to. Get it in writing.

    What to do

    • Email LARA-BCC-Rules@michigan.gov with the subject “Subscribe – PLUMBING”. It’s free.
    • Watch for the filing. You’ll have about four months after that.

    Source: LARA BCC currently open rules

    More for Plumbing contractors: Michigan Plumbing updates.