Category: Electrical

  • Michigan Skilled Trades Regulation Act explained for electricians

    The Skilled Trades Regulation Act is the state law behind every Michigan electrical license. It covers who has to be licensed, who can pull a permit, what the experience requirements are, and what happens if you work without a license. It’s a separate thing from the electrical code (the NEC as amended by Michigan) and from the skilled trades rules LARA is rewriting. This page explains how the act is put together and what it says to electricians, quoting the statute.

    What the act is

    • It’s 2016 PA 407, MCL 339.5101 to 339.6133, and it’s cited as the “skilled trades regulation act.” It took effect April 4, 2017 (MCL 339.5101; Act 407 index).
    • It replaced the separate trade acts, including former 1956 PA 217 for electricians. Licenses issued under a former act carried over until they expire, and rules made under the former acts stay in effect where they don’t conflict with the new act (MCL 339.5109).
    • It has 11 articles. Articles 1–6 apply to every trade: definitions, issuing licenses, boards, fees, complaints and investigations, and penalties. Articles 7–11 cover the trades: Article 7 electricians and electrical contractors, Article 8 mechanical contractors, Article 9 boilers, Article 10 building officials and inspectors, and Article 11 plumbers (Act 407 index).

    Act, code and rules: three different things

    • The act (PA 407) covers licensing and enforcement.
    • The licensing rules, R 339.5101–5412, are LARA’s Skilled Trades Regulation Rules, issued under sections 207, 209 and 907 of the act (R 339.5101–5412). A rewrite, 2025-58 LR, still shows Filing date: Pending as of Nov 19, 2026 (2025-58 LR tracker).
    • The electrical code, Part 8, is issued under a different law, the Stille-DeRossett-Hale single state construction code act, 1972 PA 230 (R 408.30801–30880). LARA lists the 2023 NEC as the current code, effective March 12, 2024 (LARA code books).

    Article 7: who must be licensed

    • “Only an individual who is licensed under this article shall install electrical wiring.” Where inspection service is provided, a permit is required from the board or the municipality with jurisdiction (MCL 339.5731(1)).
    • No one may engage in the business of electrical contracting without an electrical contractor’s license from the board or the appropriate municipality. An individual may not execute electrical wiring unless they’re licensed under Article 7 and employed by, and working under the direction of, a licensed electrical contractor (MCL 339.5737(1)–(2)).
    • Fire alarm work and electric sign work each require a license too (MCL 339.5731(3)–(4)).

    Work the act exempts

    MCL 339.5737(3) lists classes of work that don’t need a license. A few that come up on jobs:

    • minor repair work
    • a homeowner’s own electrical work in the single-family home and outbuildings they own and live in, or will live in
    • work by licensed mechanical contractors in certain classifications and licensed plumbing contractors, and their employees, on control wiring and electrical parts of existing mechanical and plumbing systems on the load side of the unit disconnect, except life safety wiring
    • listed lawn irrigation and landscape lighting equipment, except permanent wired connections over 30 volts
    • security alarm systems
    • telecommunications work by companies primarily in that industry (fire alarm systems are not included in this exemption)

    License levels in the act

    • Journeyman: at least 20 years old, with at least 8,000 hours of experience over at least 4 years under the direct supervision of a licensee (MCL 339.5715(1)).
    • Master: at least 22 years old, with at least 12,000 hours over 6 years or more under a master electrician’s supervision and a journeyman license held for at least 2 years (MCL 339.5713(1)).
    • Contractor: issued to a master electrician, or to a business with at least 1 full-time master electrician who lives in Michigan and is in charge of code compliance. A master can qualify only 1 contractor license (MCL 339.5711; MCL 339.5713(3)).
    • Exam retakes: fail the journeyman or master exam twice within 2 years and you wait at least 1 year. To sit again, you show you’ve completed a board-approved course on the Michigan electrical code, electrical fundamentals or electrical theory (MCL 339.5713(2); MCL 339.5715(3)).
    • Code update course: to renew, masters and journeymen must complete a board-approved course on any state construction code update within 12 months after the change (MCL 339.5713(4); MCL 339.5715(4)).

    City licenses and registration

    A municipality with its own licensing and inspection ordinance that meets the act’s standards can run its own program, and Article 7 doesn’t apply in its jurisdiction. State licenses, and municipal licenses issued under standards at least as strict, “shall be recognized by all municipalities.” Cities that provide electrical inspection can require contractors to register, but licensed journeymen don’t have to register to work in places under the board’s jurisdiction (MCL 339.5733; MCL 339.5735).

    Penalties for unlicensed work

    Practicing a regulated trade without a license, including on a suspended, revoked or lapsed license, is a misdemeanor: up to $500 and/or 90 days the first time, and up to $1,000 and/or 1 year the second time. A third or later offense is a felony, with up to $25,000 and/or 5 years. Courts can order restitution, and affected people, including licensees, can sue for an injunction (MCL 339.5601).

    What to do

    • Know which article covers you (Article 7), and keep the act, the Part 8 code rules and the R 339 licensing rules separate in your head.
    • Before you hire or sub out, confirm the license level matches the work. Use the act’s exemption list before you assume a job doesn’t need a license.
    • Watch the 2025-58 LR tracker. The act stays the same, but the rules under it are changing.

    Sources: 2016 PA 407 (MCL 339.5101–339.6133) · MCL 339.5737 · MCL 339.5601 · R 339.5101–5412 · 2025-58 LR tracker · LARA code books

    More for Electrical contractors: Michigan Electrical updates.

    Want a free sample issue? Sign up for the free sample. Pick your trades and we’ll email you the sample PDF.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Nov 19, 2026. Confirm with LARA or your local building department before you act.

  • Michigan fire alarm license: specialty technician and contractor

    Michigan treats fire alarm work as its own electrical specialty. Unless you already hold a qualifying electrical license, you need fire alarm specialty credentials before you install, alter, repair, service or maintain fire alarm system wiring and equipment.

    Why it matters

    • Except as otherwise provided in section 737, a person shall not erect, install, alter, repair, service or maintain fire alarm system wiring, devices, appliances or equipment in a building or structure without a license (MCL 339.5731(3)).
    • A “fire alarm system” is a system designed to detect and annunciate fire or by-products of fire in a building or structure. It does not include a single-station smoke detector (MCL 339.5701(k)).
    • A person that already holds a valid electrical contractor, master electrician, electrical journeyman license or apprentice electrician registration is not required to hold specialty licenses to perform specialty installations (MCL 339.5725). The fire alarm specialty path is for firms and technicians who are not working under those electrical credentials.

    Fire alarm specialty technician (FAST)

    The department issues a fire alarm specialty technician’s license to an individual who is at least 20 years old, meets Article 2 requirements, and is certified by NICET as an associate engineering technician, level II, or holds an equivalent certification in fire alarm systems technology as determined by the board (MCL 339.5721(1)).

    LARA’s electrical licensing page restates that you need NICET certification in installation and repair at Level II or higher, or an ESA Certified Fire Alarm Technician (CFAT) Level II or higher (LARA electrical licensing). Apply on LARA’s fire alarm / journeyman / master examination application; pathway rules say applicants for fire alarm specialty technician licensure submit the application, fee, proof of the most recent code-update course when applicable, then pass the exam after approval (LARA pathway to licensure).

    As a condition of renewal, the technician must complete a board-approved course on any update or change in the state construction code relating to fire alarm systems within 12 months after that update or change — only in years the code actually changes (MCL 339.5721(2)). One FAST license holder cannot be used to qualify more than one fire alarm contractor (MCL 339.5721(3)). LARA notes that without an associated FAST, a fire alarm contractor’s license is put on hold (LARA electrical licensing).

    Fire alarm contractor

    Subject to MCL 339.5731(3), the department issues a fire alarm contractor’s license to a person that meets Article 2 and either:

    • Is an individual who holds a fire alarm specialty technician’s license, or
    • Has at least one full-time employee who is a fire alarm specialty technician, resides in this state, and is actively in charge of and responsible for Michigan electrical code compliance of all fire alarm system wiring and equipment installations

    (MCL 339.5719). LARA describes the contractor license as required to do business as a FAST and requires the associated FAST to stay responsible for code compliance (LARA electrical licensing).

    Apprentice technicians

    An individual employed as a fire alarm specialty apprentice technician must register with the board within 30 days after employment. The department issues a registration certificate on proof of participation in a board-approved apprenticeship training program. The jobsite ratio is 1 fire alarm specialty technician to 2 registered apprentice technicians (MCL 339.5723). Use LARA’s electrical or FAST apprentice application (LARA electrical licensing).

    Fees and renewal dates

    From MCL 339.5707:

    • Examination fee for fire alarm contractor or fire alarm specialty technician: $100
    • Initial or renewal fire alarm specialty technician license: $50; apprentice registration: $15
    • Fire alarm contractor license: $300 for a three-year cycle (expires December 31 of every third year; renewable not later than March 1 of the renewal year)
    • Specialty technician licenses expire December 31 each year and may be renewed not more than 60 days after that date with the fee; after March 1 a non-renewed license is void and needs relicensure
    • Apprentice registration expires August 31 each year

    LARA’s renewals page covers online renewal for these electrical specialty licenses (LARA renewals).

    What to do

    • If you already hold electrical contractor / master / journeyman / apprentice credentials, MCL 339.5725 may cover fire alarm installs without a separate specialty license — confirm your license type before you bid.
    • Otherwise, earn NICET Level II (or ESA CFAT Level II+), apply for the FAST exam/license, then associate that FAST with one fire alarm contractor.
    • Register apprentices within 30 days and keep the 1-to-2 jobsite ratio.

    Sources: MCL 339.5701 · MCL 339.5719 · MCL 339.5721 · MCL 339.5723 · MCL 339.5725 · MCL 339.5731 · MCL 339.5707 · LARA electrical licensing

    Want a free sample issue? Sign up for the free sample. Pick your trades and we’ll email you the sample PDF.

    More for Electrical contractors: Michigan Electrical updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Nov 5, 2026. Confirm with LARA or your local building department before you act.

  • Michigan electrical apprentice registration: how to register and renew

    Electrical apprentices in Michigan don’t hold a license. They hold a registration. Here’s how it works and when it’s due, straight from the Skilled Trades Regulation Act and LARA.

    Who has to register, and when

    • An individual employed as an apprentice electrician must register within 30 days after employment (MCL 339.5717(1)).
    • The state issues the registration on proof that you’re in an apprenticeship training program the board approves (MCL 339.5717(2)). The board approves bona fide programs that meet or exceed U.S. Department of Labor Office of Apprenticeship requirements (MCL 339.5717(4)).
    • LARA says you need to be employed by a master electrician and an electrical contractor (sometimes the same person), and be enrolled in a related technical instruction (RTI) program (LARA electrical licensing).
    • Working in the City of Detroit? LARA says Detroit issues its own electrical licenses and registrations. Contact the city.

    How to apply

    • Use LARA’s Application for Electrical Apprentice or Fire Alarm Specialty Technician Apprentice (BCC-0704).
    • It needs three signatures: you, your sponsoring employer (master or contractor of record), and your RTI provider (a school, labor organization or your employer).
    • The employer section asks for the company’s contractor license number, your hire date and the master’s license number.
    • The fee is $15, non-refundable (MCL 339.5707(2)(c); BCC-0704). The form has a military/uniformed services fee waiver with proof of service.
    • Put your own contact information on it, not your employer’s (BCC-0704).

    The jobsite ratio

    No more than 3 registered apprentices per electrical journeyman or master electrician, enforced on a jobsite basis (MCL 339.5717(3)).

    Renewal: every August 31

    • An apprentice electrician registration expires August 31 each year. You must show a sponsoring employer for initial or renewal registration (MCL 339.5707(5)).
    • From LARA’s renewals page: you can renew starting 90 days before expiration. Log in to Accela and give your employer’s master/contractor license numbers. Express Pay doesn’t work for apprentices.
    • Renewal fee: $15. LARA lists a $100 late fee if you don’t renew on time.
    • You must have completed, or be currently enrolled in and attending, an apprenticeship program. No code-update course is required to renew.
    • Even if it’s been a long time, LARA says you renew instead of applying for a new registration. Don’t use BCC-0704 to renew.
    • LARA: you can’t be on the job site with an expired apprentice registration.

    Coming up: pending Skilled Trades rules

    The Skilled Trades Regulation Rules rewrite (2025-58 LR) has final rule language posted Sept 29, 2026. As of Oct 19, 2026, Filing and Effective dates are Pending; it takes effect 90 days after filing (state rule tracker). Two lines in the final language matter for apprentices. Neither is in effect yet:

    • “All hours submitted to sit for an electrical journeyman examination must be as a registered apprentice required under section 731(1) of the act” (final R 339.5151(4)). In plain terms: hours worked without an apprentice registration wouldn’t count toward sitting for the journeyman exam.
    • An apprentice registrant who renews more than 60 days late would pay a $20 late renewal fee “unless otherwise specified in the act” (final R 339.5116(2)).

    For reference, the journeyman license itself needs at least 8,000 hours over at least 4 years under the direct supervision of a licensee, and the applicant must be at least 20 (MCL 339.5715(1)).

    What to do

    • Contractors: register every new apprentice within 30 days of hire. Keep a copy of the signed BCC-0704.
    • Count heads on each site. One licensed journeyman or master for every 3 apprentices, max.
    • Put August 31 on the shop calendar. Renewal opens about 90 days earlier.
    • Check a registration any time in LARA’s license lookup (License Type: Electrical Apprentice).

    Sources: MCL 339.5717 · MCL 339.5707 · LARA electrical licensing · LARA renewals · 2025-58 LR tracker

    Want a free sample issue? Sign up for the free sample. Pick your trades and we’ll email you the sample PDF.

    More for Electrical contractors: Michigan Electrical updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 19, 2026. Confirm with LARA or your local building department before you act.

  • Residential wiring and the Michigan Residential Code stay

    Here’s a wrinkle that confuses a lot of electricians. The Michigan Electrical Code (Part 8, now the 2023 NEC) isn’t the whole story on houses.

    What LARA says

    LARA’s code book page, under the 2023 NEC listing: “Residential requirements are contained in the Michigan Residential Code.”

    The residential code is frozen

    • Michigan tried to move the residential code to parts of the 2021 IRC and 2021 IECC, effective Aug 29, 2025.
    • A July 7, 2025 Court of Claims order (Home Builders Assoc. et al. v. LARA et al.) stopped LARA from implementing it while the case is pending.
    • The 2015 IRC and IECC residential provisions Michigan adopted remain in effect.
    • As of Oct 15, 2026, LARA’s open rules page still says the 2015 versions “will remain valid and in effect” while the order stands.

    Which NEC applies to houses?

    The current Michigan Residential Code is built on the 2015 IRC, with its electrical chapters 34 to 43, and lists NFPA 70-2014 (the 2014 NEC) as its referenced electrical standard (Mich. Admin. Code R 408.30501 and E3401). It also allows wiring methods from the Michigan Electrical Code. Ask your inspector before you lean on any 2023 or 2026 NEC rule on a house.

    Example

    A homeowner asks for an outdoor receptacle and a new heat pump circuit. The 2026 NEC outdoor GFCI rules aren’t automatically your requirement on that house. Confirm with the local inspector which rules they’ll inspect to.

    Sources: LARA code books · LARA open rules (court order details)

    More for Electrical contractors: Michigan Electrical updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.

  • Skilled Trades rules rewrite: what electricians should know

    LARA is rewriting the Skilled Trades Regulation rules. That’s the rule set behind electrical licensing, along with plumbing, mechanical and others.

    What LARA says it does

    • Sets “clear and consistent fees and experience requirements” for registrations, licenses and exam applications.
    • Addresses continuing education requirements.
    • Clarifies complaint procedures.
    • Moves the boiler rules out into their own rule set.

    Timeline

    • Published in the Sept 1, 2026 Michigan Register.
    • Hearing Sept 10, 2026. Comments closed Sept 11.
    • Takes effect 90 days after filing. As of Oct 15, 2026, the state has not filed it or published an effective date. Final rule text went to the Legislature’s rules committee Sept 29, 2026 (state rule tracker, 2025-58 LR).

    Why it matters for an electrical shop

    Apprentice-to-journeyman and journeyman-to-master paperwork, exam fees, and possibly CE rules could change. Combined with the 2026 NEC adoption, 2027 could bring both new CE rules and a new code. The final text is on the state rule tracker. Until it’s filed and in effect, today’s fees and CE rules apply.

    What to do

    • Re-check LARA before any 2027 exam application.
    • Subscribe to LARA notices by emailing LARA-BCC-Rules@michigan.gov.

    Source: LARA BCC currently open rules

    More for Electrical contractors: Michigan Electrical updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.

  • Electrical code-update courses: when you need one

    Short answer from LARA: masters, journeymen, fire alarm specialty techs and sign specialists are “only required to take a code update course within one year of new code being adopted. This does not happen every year.”

    Who needs it

    • Master electrician: yes, within one year of new code adoption.
    • Journeyman: yes.
    • Fire alarm specialty technician: yes.
    • Sign specialist: yes.
    • Apprentices: no code-update course to renew.
    • Electrical / fire alarm / sign contractor license: not required for the contractor license itself.

    You don’t submit proof unless you’re audited. Keep a copy of your certificate.

    How many hours?

    LARA’s renewal page doesn’t list hours. Michigan’s current rule on code update courses doesn’t set hours either (Mich. Admin. Code R 339.5119). The old 15-hour (master, journeyman) and 8-hour (sign) rule was rescinded. Buy a course that’s approved for your license in CE Broker.

    Why this matters now

    Michigan is drafting the 2026 NEC adoption. Once it’s adopted, the one-year clock starts. Plan for a 2027–28 course for every licensed person in your shop.

    The law says “within 12 months after the update or change” in the state code (MCL 339.5713(4)). Neither the law nor LARA’s renewal page says whether that runs from filing or from the effective date. Ask LARA in writing.

    Tips

    • Look for courses that cover the 2026 NEC changes plus Michigan Part 8 rules, once providers update them.
    • Don’t take a 2023 NEC course to satisfy a 2026 adoption.

    Sources: LARA BCC license renewals · LARA open rules

    More for Electrical contractors: Michigan Electrical updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.

  • Michigan electrical license renewals: Dec 31 and beyond

    Most Michigan electrical licenses renew every year by December 31. Renewal opens 90 days early, so you can do it now.

    License Renews Fee Late fee
    Master electrician Every year by Dec 31 $50 $50
    Journeyman electrician Every year by Dec 31 $40 $50
    Fire alarm specialty technician Every year by Dec 31 $50 $50
    Sign specialist Every year by Dec 31 $40 $50
    Electrical / fire alarm / sign contractor Every 3 years by Dec 31 $300 $50
    Electrical apprentice Every year by Aug 31 $15 $100

    How

    • Express Pay works without logging in for most licenses.
    • Apprentices must log into Accela and enter their employer’s master or contractor license numbers. Express Pay isn’t available for them.

    What goes wrong

    • You can’t be on a job site with an expired license. LARA says it “may lead to citations and/or enforcement action.”
    • A lapsed master hurts the apprentices and journeymen whose hours you sign.
    • A contractor license is placed on hold if its qualifying master’s license lapses, until they renew and you notify LARA. An expired contractor license can affect your ability to pull permits.
    • An apprentice should not be on a job site with an expired registration. LARA says that’s against the law.

    Example

    Your journeyman forgets until January 5. He pays $40 plus the $50 late fee, and he shouldn’t be on the job in the meantime. That’s more than the fee in lost billable hours. Do it in November.

    Source: LARA BCC license renewals

    More for Electrical contractors: Michigan Electrical updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.

  • Michigan Electrical Code is moving to the 2026 NEC: where it stands

    Michigan’s electrical code (Part 8) currently adopts the 2023 NEC, in effect since March 12, 2024. LARA has drafted rules to move to the 2026 NEC.

    Where it stands

    • Rule set: Construction Codes, Part 8. Electrical Code, LARA number 2026-17 LR.
    • LARA’s request for rulemaking says the rules would adopt the 2026 NEC “with amendments, deletions, and additions.”
    • A public rules advisory meeting on the draft was held Aug 27, 2026.
    • The draft says the rules “become effective 120 days after filing with the secretary of state.”
    • The draft adopts the 2026 NEC second printing, plus listed TIAs and errata. It also updates NFPA 110 and NFPA 111 to their 2025 editions.

    Still a draft. As of Oct 15, 2026, the state has not scheduled a public hearing, filed the rules, or published an effective date (state rule tracker, 2026-17 LR). The 2023 NEC governs for now.

    Houses are different

    LARA’s code book page notes that residential requirements are in the Michigan Residential Code, and that update is stuck in court. Don’t assume a 2026 NEC adoption changes one- and two-family work right away. Ask your inspector.

    What it means for you

    1. A code-update course will be required. Masters, journeymen, fire alarm techs and sign specialists take one within a year of new code adoption. See the CE explainer.
    2. Learn the 2026 changes. See key 2026 NEC changes. Michigan’s amendments could change any of them.

    What to do

    • Subscribe: email LARA-BCC-Rules@michigan.gov with the subject “Subscribe – ELECTRICAL”.
    • Read the strike-bold draft if you want the Michigan amendments early.

    Sources: LARA open rules · Draft rules (strike-bold) · LARA code books

    More for Electrical contractors: Michigan Electrical updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.

  • Key 2026 NEC changes a small Michigan shop should know

    Michigan is drafting its move to the 2026 NEC. Here’s what changed nationally, mostly from NFPA’s own summary. Caveat: Michigan’s Part 8 rules amend and delete sections. Michigan’s Aug 19, 2026 draft is posted, and it can still change. Check a section there before you count on it.

    Structure moved around

    • Load calculations moved from Article 220 to new Article 120 in Chapter 1.
    • Energy management systems moved to new Article 130.
    • New Chapter 2 articles (265–270) cover systems over 1000 V ac / 1500 V dc.
    • Chapter 7 was reorganized around limited-energy systems (Articles 720–750). A lot of Chapter 8 content moved into it.

    Your section numbers from memory won’t match anymore. Budget time to relearn where things are.

    Dwelling load calcs

    • General lighting and receptacle load dropped from 3 VA/ft² to 2 VA/ft² for dwelling units. That could shrink calculated service sizes.
    • But new 120.13 keeps branch-circuit counts based on 3 VA/ft², so you don’t end up with fewer circuits.
    • 120.5(E) changes how continuous loads are handled.
    • 120.7 lets a power control system (PCS) be factored into load calcs.
    • Dryer demand factors (Table 120.54) eased for multifamily.

    Outdoor GFCI and HVAC

    • 210.8(F): outdoor outlets 60 A or less at dwellings need GFCI protection.
    • New Exception No. 3 allows a listed Class C SPGFCI (UL 943C) for listed HVAC equipment. The old HVAC exception (No. 2) expired Sept 1, 2026.
    • Industry coverage (EC&M) says the HVAC disconnect must be marked when Class C SPGFCI protection is used. See our HVAC-side explainer.

    Receptacles

    • 210.52(A)(5): wall or floor receptacles can’t be installed less than 24 in. below the top of a countertop or work surface. There’s an exception for receptacles in drawers.

    Services (from industry coverage)

    EC&M reports that 230.70(A)(1) now requires one- and two-family dwelling service disconnects in a readily accessible outdoor location, on or within sight of the house, merged with the emergency disconnect requirement. It also reports surge protection expanded to more occupancies. This comes from trade press. NFPA’s code text isn’t free to quote, so read 230.70 in the 2026 NEC. Michigan’s draft drops its own separate emergency-disconnect amendment (old 230.85) (draft).

    Other

    • Article 426: conductive pavement heating systems.
    • Article 624: power transfer for off-road electric vehicles: golf carts, forklifts, boats.

    Sources: NFPA: Key Changes in the 2026 NEC · EC&M: Key Changes to the ’26 NEC

    More for Electrical contractors: Michigan Electrical updates.

    Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.