Michigan mechanical contractor license: classifications and requirements

Written by

in

Michigan licenses mechanical work by classification. One mechanical contractor license can carry several. The list and the experience rules are in the Skilled Trades Regulation Act, not in a local city ordinance.

Who needs a mechanical contractor license

Under MCL 339.5809, you generally need a mechanical contractor’s license (with the right classification) and the appropriate permit before you install, alter or service work in the classifications below. LARA’s mechanical page says licensed mechanical contractors can perform installations, alterations and servicing, and secure permits.

A municipality can’t invent its own mechanical licensing requirements for those classifications (MCL 339.5811).

The work classifications

MCL 339.5807(2) lists these classifications. LARA’s mechanical licensing page lists the same ones:

  1. Hydronic heating and cooling and process piping
  2. HVAC equipment
  3. Ductwork
  4. Refrigeration
  5. Limited heating service
  6. Limited refrigeration and air conditioning service
  7. Unlimited heating service
  8. Unlimited refrigeration and air conditioning service
  9. Fire suppression
  10. Specialty

“Limited” and “unlimited” service, and what “specialty” covers (solar heating and cooling; solid fuel and vented decorative gas appliances; LP distribution piping; fuel gas piping; fuel gas piping and venting), are defined in MCL 339.5803 and in R 339.5161. If you already hold the HVAC equipment classification, R 339.5161(2) says you don’t also need those specialty licenses for that specialty work.

Experience and exams

  • For a new classification, you generally need 3 years or 6,000 hours of experience in that classification, shown with employer statements signed under penalty of perjury (MCL 339.5807(1)(a)). LARA restates the same rule on its mechanical licensing page.
  • A completed 2-year (or equivalent) HVAC program from a recognized school, or a USDOL-approved 2-year HVAC training program, can count for up to 1 year / 2,000 hours of that experience (MCL 339.5807(5)).
  • Military experience can count with the right discharge papers and a commanding-officer affidavit (MCL 339.5807(3)–(4)).
  • Adding a classification to an existing license: LARA’s experience-requirements notice says you must have held the prerequisite classification for at least 3 years immediately before you apply (for example, ductwork requires HVAC equipment). The statute sets out the same prerequisite pairs as a route to eligibility (MCL 339.5807(1)(b)).
  • You must take and pass an exam for each classification you want. PSI runs the exams; approved applicants schedule with PSI and pay the exam fee to PSI (LARA mechanical page).

Fees and renewal

  • LARA’s experience notice: initial mechanical contractor license/classification application fee $300 (non-refundable). Adding a classification mid-cycle: $300 / $200 / $100 depending on year of the license cycle.
  • Renewal: every three years by August 31. Not every contractor renews in the same year. Renewal fee $300; late fee $100 if you miss the deadline (LARA renewals). You can start renewing 90 days before expiration.
  • If the license has been expired more than 3 years, LARA says you re-apply and re-test.
  • LARA’s renewals page says you are not required to take code-update courses for a mechanical contractor license under the rules in force today.

Coming up: pending Skilled Trades rules

The Skilled Trades Regulation Rules rewrite (2025-58 LR) has final rule language and a JCAR report posted Sept 29, 2026. As of Oct 19, 2026, its Filing date and Effective date are Pending, and the final rules say they take effect 90 days after filing (state rule tracker, 2025-58 LR). The final language of R 339.5161 would add three things for mechanical contractors. These are not in effect yet:

  • Code-update course at renewal: “As a condition of renewal of a mechanical contractor license, a mechanical contractor shall demonstrate the successful completion of a course, approved by the department, concerning any update or change in the Stille-DeRossett-Hale single state construction code act, 1972 PA 230, MCL 125.1501 to 125.1531, within 12 months after the update or change in that code.” It applies only in or after years the code changes.
  • Boiler route to hydronic: holding at least a low-pressure boiler installer license for at least 1 year could stand in for experience for classification 1, hydronic heating and cooling and process piping.
  • Adding a classification: submit the department’s application with the non-refundable application fee.

Michigan is also moving to the 2024 IMC (rule set 2025-7 LR, filing Pending). If both take effect, the code-update course rule would matter for that change. See our 2024 IMC post below.

What to do

  • Confirm which classifications your company actually holds before you bid a fire-suppression, hydronic or unlimited-service job.
  • Apply and renew through Accela: aca-prod.accela.com/LARA.
  • Use LARA’s mechanical contractor application and keep the employer statements detailed (BTU ratings, refrigerants, equipment types, dates).

Sources: MCL 339.5807 · MCL 339.5809 · MCL 339.5803 · LARA mechanical licensing · LARA renewals · R 339.5101–5412

Want a free sample issue? Sign up for the free sample. Pick your trades and we’ll email you the sample PDF.

More for HVAC/Mechanical contractors: Michigan HVAC/Mechanical updates.

Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 19, 2026. Confirm with LARA or your local building department before you act.