Residential wiring and the Michigan Residential Code stay

Written by

in

Here’s a wrinkle that confuses a lot of electricians. The Michigan Electrical Code (Part 8, now the 2023 NEC) isn’t the whole story on houses.

What LARA says

LARA’s code book page, under the 2023 NEC listing: “Residential requirements are contained in the Michigan Residential Code.”

The residential code is frozen

  • Michigan tried to move the residential code to parts of the 2021 IRC and 2021 IECC, effective Aug 29, 2025.
  • A July 7, 2025 Court of Claims order (Home Builders Assoc. et al. v. LARA et al.) stopped LARA from implementing it while the case is pending.
  • The 2015 IRC and IECC residential provisions Michigan adopted remain in effect.
  • As of Oct 15, 2026, LARA’s open rules page still says the 2015 versions “will remain valid and in effect” while the order stands.

Which NEC applies to houses?

The current Michigan Residential Code is built on the 2015 IRC, with its electrical chapters 34 to 43, and lists NFPA 70-2014 (the 2014 NEC) as its referenced electrical standard (Mich. Admin. Code R 408.30501 and E3401). It also allows wiring methods from the Michigan Electrical Code. Ask your inspector before you lean on any 2023 or 2026 NEC rule on a house.

Example

A homeowner asks for an outdoor receptacle and a new heat pump circuit. The 2026 NEC outdoor GFCI rules aren’t automatically your requirement on that house. Confirm with the local inspector which rules they’ll inspect to.

Sources: LARA code books · LARA open rules (court order details)

More for Electrical contractors: Michigan Electrical updates.

Michigan Code Brief · Not legal advice. Every fact links to its official source. Checked Oct 15, 2026. Confirm with LARA or your local building department before you act.